Fujitsu · KLLA
Fujitsu ARXG18KLLAP ducted air conditioner
- Heating
- 6 kW
- Cooling
- 5.2 kW
- SCOP
- 4.1A+
- SEER
- 6.2A++
- Noise from
- 27 dB(A)
- Heats down to
- -15 °C
Recommended for rooms of 36 to 52 m²
Price on request
About the KLLA series
The KLLA series is a slim ducted unit for low static pressure, designed to fit narrow spaces under the ceiling. Static pressure can be selected over a wide range and set from the remote controller, and the return air can be drawn in from the rear or from below to suit the installation. A condensate drain pump comes as standard. An optional grille with motorised louvres spreads the air evenly through the room.
Certified heating data
Numbers from independent certification, not from advertising. Each row holds for the exact combination measured.
Eurovent · air to air
SCOP 4.1A+
- Design load
- 4.4 kW
- Rated heating capacity (+7 °C)
- 6 kW
- At -7 °C, at least
- 3.89 kW
- At -10 °C, at least
- 3.25 kW
- Lowest temperature in the rating
- -15 °C
For this climate the rating covers heating down to -15 °C, with measured output down to -10 °C; it is not the unit’s operating limit.
Measured combination: AOYG18KBTB/
The rating tests the unit on an imaginary reference house. The design load is what that house needs at the design temperature (−10 °C in the average European climate), not the unit’s capacity; where the unit falls short of it, the rating assumes an electric backup heater covers the difference. The “at least” figures show what the unit delivered to that house at the stated temperature, not the most it can give.
According to the manufacturer, the unit heats down to an outdoor temperature of -15 °C.
Technical data
| Cooling capacity (kW) | 5.2 |
|---|---|
| Cooling range (kW) | 0.9 – 5.9 |
| Heating capacity (kW) | 6 |
| Heating range (kW) | 0.9 – 7.5 |
| Energy class, cooling | A++ |
| Energy class, heating | A+ |
| SEER | 6.2 |
| SCOP | 4.1 |
| Power input, cooling (W) | 1,550 |
| Power input, heating (W) | 1,620 |
| Indoor unit noise (dB(A)) | 27 – 32 |
| Outdoor unit noise (dB(A)) | 50 |
| Airflow (m³/h) | 940 |
| Refrigerant | R32 |
| Refrigerant charge (kg) | 1.02 |
| Pipe, liquid | 6.35 mm |
| Pipe, gas | 12.7 mm |
| Maximum pipe length (m) | 30 |
| Maximum height difference (m) | 20 |
| Power supply | 230 V / 1 f / 50 Hz |
| Indoor unit, W × H × D (mm) | 900 × 198 × 620 |
| Outdoor unit, W × H × D (mm) | 799 × 632 × 290 |
| Indoor unit weight (kg) | 20 |
| Outdoor unit weight (kg) | 36 |
| Static pressure (Pa) | 90 |
| Heats down to outdoor (°C) | -15 |
Manufacturer's data.
The set consists of
Documents
They open on the manufacturer's site.