Fujitsu General · LVTA
Fujitsu General ABYG24LVTA floor-ceiling air conditioner
- Heating
- 8 kW
- Cooling
- 6.8 kW
- SCOP
- 3.9A
- SEER
- 5.6A+
- Noise from
- 35 dB(A)
- Heats down to
- -15 °C
Recommended for rooms of 48 to 68 m²
- Price for cash or bank transfer
- 3,700 KM
- Price for cards and card instalments
- 4,113 KM
Prices include VAT, not installation.
About the LVTA series
The LVTA series is an indoor unit that can be mounted under the ceiling or placed at floor level as a floor console, so it adapts to the room. The louvers swing automatically up and down as well as left and right, directing the airflow both vertically and across the room. The fan is driven by a powerful, efficient DC motor, and the unit has a mould-resistant dust filter and a super quiet fan speed.
Heating data
This model is no longer in independent certification (Eurovent), so these are the figures from the manufacturer’s EU information sheet, which the law requires for every model. They are the quantities Eurovent checks; for models still certified the figures are the same.
Manufacturer’s EU sheet · air to air
SCOP 3.9A
- Design load
- 6 kW
- At -7 °C, at least
- 5.31 kW
- At -10 °C, at least
- 4.91 kW
- Lowest temperature in the sheet
- -15 °C
For this climate the sheet covers heating down to -15 °C, with output given down to -10 °C; it is not the unit’s operating limit.
Measured combination: AOYG24LBCB/
Like a certificate, the EU sheet rates the unit on an imaginary reference house. The design load is what that house needs at the design temperature (−10 °C in the average European climate), not the unit’s capacity; where the unit falls short of it, an electric backup heater is assumed to cover the difference. The “at least” figures show what the unit delivered to that house at the stated temperature, not the most it can give.
According to the manufacturer, the unit heats down to an outdoor temperature of -15 °C.
Technical data
| Cooling capacity (kW) | 6.8 |
|---|---|
| Cooling range (kW) | 0.9 – 8 |
| Heating capacity (kW) | 8 |
| Heating range (kW) | 0.9 – 9.1 |
| Energy class, cooling | A+ |
| Energy class, heating | A |
| SEER | 5.6 |
| SCOP | 3.9 |
| Power input, cooling (W) | 2,210 |
| Power input, heating (W) | 2,260 |
| Indoor unit noise (dB(A)) | 35 – 48 |
| Outdoor unit noise (dB(A)) | 53 |
| Airflow (m³/h) | 980 |
| Refrigerant | R410A |
| Refrigerant charge (kg) | 1.5 |
| Pipe, liquid | 6.35 mm |
| Pipe, gas | 15.88 mm |
| Maximum pipe length (m) | 30 |
| Maximum height difference (m) | 20 |
| Power supply | 230 V / 1 f / 50 Hz |
| Indoor unit, W × H × D (mm) | 990 × 199 × 655 |
| Outdoor unit, W × H × D (mm) | 820 × 716 × 315 |
| Indoor unit weight (kg) | 27 |
| Outdoor unit weight (kg) | 42 |
| Heats down to outdoor (°C) | -15 |
Manufacturer's data.
The set consists of
Documents