Skip to content
Fujitsu WSYA080ML3/WOYA080KLT air-to-water heat pump

Fujitsu · Waterstage Comfort

Fujitsu WSYA080ML3/WOYA080KLT single-phase air-to-water heat pump

Heating
7.5 kW
SCOP (55 °C)
3.28
Energy class (35 °C)
A+++
Water up to
55 °C
Heats down to
-20 °C
Price for cash or bank transfer
8,300 KM
Price for cards and card instalments
9,225 KM

Prices include VAT, not installation.

About the Waterstage Comfort series

The Waterstage Comfort series is a split air-to-water heat pump with a wall-mounted hydraulic module, for heating through underfloor heating or radiators. With an optional tank it also prepares domestic hot water, and the hydraulic module has a built-in backup electric heater. The controller sets the water temperature from a heating curve and the outdoor temperature, and with an optional kit it controls a lower and a higher temperature circuit separately, for example underfloor heating and radiators.

Certified heating data

Numbers from independent certification, not from advertising. Each row holds for the exact combination measured.

HP KEYMARK · water 35 °C (underfloor heating)

SCOP 4.5

Design load
6.5 kW
Rated heating capacity (+7 °C)
7.5 kW
At -7 °C, at least
5.8 kW
At -10 °C, at least
5.6 kW

Measured combination: WOYA080KLT/WSYA080ML3

View the certificate

HP KEYMARK · water 55 °C (radiators)

SCOP 3.28

Design load
6.2 kW
Rated heating capacity (+7 °C)
7 kW
At -7 °C, at least
5.5 kW
At -10 °C, at least
5 kW

Measured combination: WOYA080KLT/WSYA080ML3

View the certificate

The rating tests the unit on an imaginary reference house. The design load is what that house needs at the design temperature (−10 °C in the average European climate), not the unit’s capacity; where the unit falls short of it, the rating assumes an electric backup heater covers the difference. The “at least” figures show what the unit delivered to that house at the stated temperature, not the most it can give.

According to the manufacturer, the unit heats down to an outdoor temperature of -20 °C.

Heating capacity by outdoor temperature

The manufacturer's data from the design & technical manual: the maximum heating capacity at the outdoor temperature and the water temperature of the system. The calculator chooses a model by this table; the certified data above is what was measured independently.

OutdoorWater 35 °CWater 45 °CWater 55 °C
−20 °C3.97 kW––
−15 °C6.01 kW5.68 kW–
−10 °C7.11 kW6.71 kW5.33 kW
−7 °C7.05 kW6.67 kW5.85 kW
−5 °C7.45 kW7.04 kW6.19 kW
0 °C8.23 kW7.78 kW7.05 kW
7 °C9.64 kW9.12 kW8.22 kW

Source: Fujitsu General, Design & Technical Manual, heating capacity table. Open the manual

Technical data

Heating capacity (kW)7.5
Energy class, water 35 °C (underfloor)A+++
Energy class, water 55 °C (radiators)A++
SCOP3.28
Power input, heating (W)1,690
RefrigerantR32
Refrigerant charge (kg)1.02
Pipe, liquid6.35 mm
Pipe, gas12.70 mm
Maximum pipe length (m)30
Maximum height difference (m)20
Power supply230 V / 1 f / 50 Hz
Indoor unit, W × H × D (mm)450 × 847 × 493
Outdoor unit, W × H × D (mm)820 × 716 × 315
Indoor unit weight (kg)41
Outdoor unit weight (kg)42
Heats down to outdoor (°C)-20
Maximum water temperature (°C)55

Manufacturer's data.

The set consists of

Documents

They open on the manufacturer's site.

Also known as: WSHA080ML3/WOHA080KLT